H1 was most of the way through relocking after an unrelated(?) lockloss. IMC started losing lock during relocking attempts when I noticed a vertical line starting to appear on the BLRMS. L1 has been down due to microseism for several hours.
-
Reported on both USGS and Terramon by the time I noticed its effects
-
Magnitude 7.9 near Papua New Guinea (initially reported as an 8.0)
-
First noticed on BLRMS around 11:12 UTC. Terramon reports that R-wave arrival should have been around 11:39 UTC(3:39 PT).
-
H1 was in lock acquistion at the time of arrival. IMC having trouble locking was my first indication of an EQ.
This EQ was large enough (10^2 um/s in the EQ band according to the BLRMS) that it tripped every ISI platform and several SUSes. I switched ISI_CONF to LARGE_EQ_NOBRSXY, but it didn't seem to help the end station ISIs.