Reports until 05:39, Monday 19 December 2016
H1 PSL (PSL)
peter.king@LIGO.ORG - posted 05:39, Monday 19 December 2016 (32727)
alignment into the reference cavity
The transmission through the reference cavity has deteriorated somewhat since the last touch up alignment
last week.  Went through the usual signals to see if anything matched up.  Nothing from the usual signals.
However this time there seems to be coincidence with the horizontal output of the quadrant photodetector
in the ISS box.  That in turn implies that the pointing out of the pre-modecleaner changed.

    The change in horizontal seems to coincide with the drive voltage to the pre-modecleaner heater.  From
the cavity transmission camera, it is obvious that the alignment has drifted in both pitch and yaw.
Images attached to this report