Evan G., Aaron V.
I have checked a new filters file into the calibration SVN for offline (C01) calibration. The filters were made using revision #3987 using the script
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/Scripts/TDfilters/H1_run_td_filters_1165799036.m
The file can be found here:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/GDSFilters/H1DCS_1165799036.npz
In order to achieve agreement with GDS calibration, it was necessary to add a delay of 2 16kHz clock cycles to the actuation filters. Evan G. is reviewing the DARM model codes to determine where this timing discrepancy originated.
The attached plots include:
1) h(t) spectrum from CALCS and DCS
2) ASD ratio (DCS / CALCS)
3 - 5) plots of filters and errors