J. Kissel While Nutsinee and I were trying to debug why SRCL would not trigger during SRY initial alignment sequence, I noticed that SR3's ODC vector showed red. As I've seen in several suspensions, it was the comparison between a user-entered-but-rarely-paid-attention-to "H1:SUS-SR3_M1_DAMP_[DOF]_STATE_GOOD" channel that was not set to match the current state of the filters, "H1:SUS-SR3_M1_DAMP_[NOW]_STATE_NOW." This appears to have gone bad on Nov 17 2016 00:26 UTC (Nov 16 2016 16:26:00 PST), when Sheila added highest vertical and roll mode notches for the HLTS -- see LHO aLOG 31553. Fixed now. Doesn't matter, but one less bit of red to distract people. Changes have been accepted in the SDF system in both the SAFE and OBSERVE.snaps.