Displaying report 1-1 of 1.
Reports until 13:15, Sunday 25 December 2016
H1 DAQ (CDS, DAQ)
david.barker@LIGO.ORG - posted 13:15, Sunday 25 December 2016 - last comment - 13:27, Sunday 25 December 2016(32868)
h1tw0 has raid problems again, stopping its daqd for now

h1tw0 (secondary minute trend writer) started having RAID issues again beginning at 05:35 PST this morning. Its been in a start-stop-restart cycle ever since. I've turned off monit on h1tw0 to stop it respawning. We'll rely on h1tw1 for the rest of the holidays.

Comments related to this report
david.barker@LIGO.ORG - 13:27, Sunday 25 December 2016 (32869)

The DAQ EDCU is now not green (purple) because of the loss of h1tw0. To confirm, you can run the command h1dc0_edcu_list_disconnected_epics_channels.py and verify all 57 chans are from H1:DAQ-TW0

david.barker@zotws2: h1dc0_edcu_list_disconnected_epics_channels.py 

daqd> 

33796 channels

33739 connected

57 disconnected

80237 connection events processed

2220990763 value change events processed

H1:DAQ-TW0_CYCLE

H1:DAQ-TW0_TOTAL_CHANS

H1:DAQ-TW0_DATA_RATE

H1:DAQ-TW0_EDCU_CHANS

H1:DAQ-TW0_EDCU_CONN_CHANS

H1:DAQ-TW0_UPTIME_SECONDS

H1:DAQ-TW0_LOOKBACK_RAM

H1:DAQ-TW0_LOOKBACK_FULL

H1:DAQ-TW0_LOOKBACK_DIR

H1:DAQ-TW0_LOOKBACK_STREND

H1:DAQ-TW0_LOOKBACK_STREND_DIR

H1:DAQ-TW0_LOOKBACK_MTREND

H1:DAQ-TW0_LOOKBACK_MTREND_DIR

H1:DAQ-TW0_FAST_DATA_CRC

H1:DAQ-TW0_FAULT

H1:DAQ-TW0_BCAST_RETR

H1:DAQ-TW0_BCAST_FAILED_RETR

H1:DAQ-TW0_GPS

H1:DAQ-TW0_CHANS_SAVED

H1:DAQ-TW0_FRAME_SIZE

H1:DAQ-TW0_SCIENCE_FRAME_SIZE

H1:DAQ-TW0_SCIENCE_TOTAL_CHANS

H1:DAQ-TW0_SCIENCE_CHANS_SAVED

H1:DAQ-TW0_FRAME_WRITE_SEC

H1:DAQ-TW0_SCIENCE_FRAME_WRITE_SEC

H1:DAQ-TW0_SECOND_FRAME_WRITE_SEC

H1:DAQ-TW0_MINUTE_FRAME_WRITE_SEC

H1:DAQ-TW0_SECOND_FRAME_SIZE

H1:DAQ-TW0_MINUTE_FRAME_SIZE

H1:DAQ-TW0_RETRANSMIT_TOTAL

H1:DAQ-TW0_PRDCR_TIME_FULL_MEAN_MS

H1:DAQ-TW0_PRDCR_TIME_FULL_MIN_MS

H1:DAQ-TW0_PRDCR_TIME_FULL_MAX_MS

H1:DAQ-TW0_PRDCR_TIME_RECV_MEAN_MS

H1:DAQ-TW0_PRDCR_TIME_RECV_MIN_MS

H1:DAQ-TW0_PRDCR_TIME_RECV_MAX_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_FULL_MEAN_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_FULL_MIN_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_FULL_MAX_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_CRC_MEAN_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_CRC_MIN_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_CRC_MAX_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_XFER_MEAN_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_XFER_MIN_MS

H1:DAQ-TW0_PRDCR_CRC_TIME_XFER_MAX_MS

H1:DAQ-TW0_PROFILER_FREE_SEGMENTS_MAIN_BUF

H1:DAQ-TW0_RAW_FW_STATE

H1:DAQ-TW0_RAW_FW_DATA_STATE

H1:DAQ-TW0_RAW_FW_DATA_SEC

H1:DAQ-TW0_SCIENCE_FW_STATE

H1:DAQ-TW0_SCIENCE_FW_DATA_STATE

H1:DAQ-TW0_SCIENCE_FW_DATA_SEC

H1:DAQ-TW0_STREND_FW_STATE

H1:DAQ-TW0_MTREND_FW_STATE

H1:DAQ-TW0_FRAME_CHECK_SUM_TRUNC

H1:DAQ-TW0_SECOND_FRAME_CHECK_SUM_TRUNC

H1:DAQ-TW0_MINUTE_FRAME_CHECK_SUM_TRUNC

Total 57 disconnected.

Displaying report 1-1 of 1.