Displaying report 1-1 of 1.
Reports until 06:44, Thursday 28 June 2012
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 06:44, Thursday 28 June 2012 - last comment - 08:52, Thursday 28 June 2012(3287)
Starting measurements of H2 SUS ETMY
Just a heads up: while y'all are asleep, I'muna gunna take some active measurements of ETMY, and perhaps gather some quiescent spectra of the TOP stage of TMSY while those are running. I hope to be done in 2 hours, starting from 9:30a ET, 6:30a PT. I have reserved this amount of time on the CDS reserve systems MEDM as well. Please, don't hesitate to call if you need me (617 452 3605) to stop before hand -- otherwise, consider me to be done at 11:30 ET, or 8:30a PT.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 08:51, Thursday 28 June 2012 (3288)
Notes for later:

Measurement conditions:
BSC6-HPI is ON (Position feedback loops only), WD ARMED
BSC6-ISI is ON (Damping loops only), WD ARMED
H2SUSETMY 
 - damping loops OFF, 
 - P&Y offsets have been removed (they were P 2804 [ct] and Y 14443 [ct])
 - Coil Drivers in State 1, COIL enabled (LP OFF, or "ACQ") (and "properly" compensated)
 - All WDs ARMED (Thresh OSEM DC = [-30e3:30e3] OSEM AC = [20e3], ACT AC [55555])

Driving through the damping filters 
 - inputs off, 
 - default legacy filters ON 
 - default legacy gains ON
     - [L, T, V, R, P, Y] = [-1, -5, -2, -0.3, -0.1, -0.1]

Open Loop TF is from DAMP_EXC through FMs 1 and 10, response is DAMP_IN1, so OLG TF is in the same units of Sensor [ct]/ Sensor [ct], so it accurately represents the open loop gain.
Plant TF is uncalibrated, but the only calibration necessary is the usual scale factor of 60, so we can treat it as calibrated * 60.


Reference data from 2012-04-14 data set

Drive amplitudes (Started with standard out-of-loop, from TEST_EXC, TF templates):
[[ Watched for / confirm no ]] DAC saturations
L = 1000 [ct] (was 4500 [ct]); AC RMS = [F2, F3] = [4.4e3, 4.4e3]
P = 200 [ct] (was 200 [ct]); ACT AC RMS during meas: [F1, F2, F3] = [3e3, 1.6e3, 1.6e3]
Y = 300 [ct] (was 300 [ct]); ACT AC RMS during meas: [F2, F3] = [1.5e3, 1.5e3]

Data saved to .xmls:
SusSVN = /ligo/svncommon/SusSVN/sus/trunk/
${SusSVN}/QUAD/H2/ETMY/SAGM0/Data/
2012-06-28_1358_H2SUSETMY_M0_Mono_L_WhiteNoise_OLGTF.xml
2012-06-28_1358_H2SUSETMY_M0_Mono_P_WhiteNoise_OLGTF.xml
2012-06-28_1358_H2SUSETMY_M0_Mono_Y_WhiteNoise_OLGTF.xml
jeffrey.kissel@LIGO.ORG - 08:52, Thursday 28 June 2012 (3289)
I've finished these measurements. Stay tuned for data and analysis!!
Displaying report 1-1 of 1.