Displaying report 1-1 of 1.
Reports until 12:41, Tuesday 03 January 2017
H1 SEI
jim.warner@LIGO.ORG - posted 12:41, Tuesday 03 January 2017 (32922)
Seismometer Center Check - FAMIS Task 6082

Looks like a number of seismometers are out of shape, especially the corner station ground STS, 6 volts seems pretty bad relative to the 2 volt spec.

 

Averaging Mass Centering channels for 10 [sec] ...


2017-01-03 12:04:38.352808
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS B DOF Y/V = -6.441 [V]
STS B DOF Z/W = 4.384 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.486 [V]
STS A DOF Y/V = 0.035 [V]
STS A DOF Z/W = -0.568 [V]
STS B DOF X/U = 0.986 [V]
STS C DOF X/U = -0.0 [V]
STS C DOF Y/V = -0.0 [V]
STS C DOF Z/W = -0.0 [V]
STS EX DOF X/U = -0.089 [V]
STS EX DOF Y/V = 0.557 [V]
STS EX DOF Z/W = 0.126 [V]
STS EY DOF X/U = 0.168 [V]
STS EY DOF Y/V = 0.084 [V]
STS EY DOF Z/W = 0.464 [V]


Assessment complete.

jim.warner@opsws0:~ 0$ t240_center  
Averaging Mass Centering channels for 10 [sec] ...
2017-01-03 12:16:41.356637


There are 12 T240 proof masses out of range ( > 0.3 [V] )!
ETMY T240 3 DOF Z/W = 0.405 [V]
ITMX T240 1 DOF X/U = -0.589 [V]
ITMX T240 1 DOF Y/V = 0.355 [V]
ITMX T240 1 DOF Z/W = 0.31 [V]
ITMX T240 2 DOF X/U = 0.346 [V]
ITMX T240 2 DOF Y/V = 0.35 [V]
ITMX T240 2 DOF Z/W = 0.358 [V]
ITMX T240 3 DOF X/U = -0.573 [V]
ITMY T240 2 DOF Z/W = 0.306 [V]
ITMY T240 3 DOF Z/W = -1.025 [V]
BS T240 1 DOF Z/W = 0.423 [V]
BS T240 2 DOF Y/V = 0.393 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.136 [V]
ETMX T240 1 DOF Y/V = 0.099 [V]
ETMX T240 1 DOF Z/W = 0.157 [V]
ETMX T240 2 DOF X/U = -0.137 [V]
ETMX T240 2 DOF Y/V = -0.252 [V]
ETMX T240 2 DOF Z/W = 0.039 [V]
ETMX T240 3 DOF X/U = 0.091 [V]
ETMX T240 3 DOF Y/V = 0.075 [V]
ETMX T240 3 DOF Z/W = 0.085 [V]
ETMY T240 1 DOF X/U = 0.046 [V]
ETMY T240 1 DOF Y/V = -0.065 [V]
ETMY T240 1 DOF Z/W = -0.099 [V]
ETMY T240 2 DOF X/U = 0.256 [V]
ETMY T240 2 DOF Y/V = -0.135 [V]
ETMY T240 2 DOF Z/W = 0.038 [V]
ETMY T240 3 DOF X/U = -0.108 [V]
ETMY T240 3 DOF Y/V = 0.049 [V]
ITMX T240 3 DOF Y/V = 0.281 [V]
ITMX T240 3 DOF Z/W = 0.262 [V]
ITMY T240 1 DOF X/U = 0.228 [V]
ITMY T240 1 DOF Y/V = 0.153 [V]
ITMY T240 1 DOF Z/W = 0.19 [V]
ITMY T240 2 DOF X/U = 0.092 [V]
ITMY T240 2 DOF Y/V = 0.272 [V]
ITMY T240 3 DOF X/U = -0.111 [V]
ITMY T240 3 DOF Y/V = 0.265 [V]
BS T240 1 DOF X/U = 0.031 [V]
BS T240 1 DOF Y/V = 0.13 [V]
BS T240 2 DOF X/U = 0.231 [V]
BS T240 2 DOF Z/W = 0.218 [V]
BS T240 3 DOF X/U = 0.253 [V]
BS T240 3 DOF Y/V = 0.073 [V]
BS T240 3 DOF Z/W = 0.092 [V]


Assessment complete.
 

Displaying report 1-1 of 1.