edmond.merilh@LIGO.ORG - posted 20:15, Wednesday 04 January 2017 (32978)
Mid-Shift Summary
Showed up to a locked, observing H1 - Fire Alarm then lockloss (see previous aLog)
Had some trouble re-aligning arms. PRM had some issues that Jenne and Sheila had to work out - Thank you ladies!
Spoke to Joe Hanson a couple of times at LLO on the telephone as he didn't realize that his TeamSpeak was a little "hosed"
I ran a2l once H1 was back to NLN and as I look at it now, it seems to have come apart a little in YAW and perhaps our range is suffering a bit from it.
Jenne cleared some SDF artifacts of hers and the Intention bit was set to Observing.
I called LLO to inform them of our intention bit as GWIstat issue is still in process
Everything seems to be holding steady. No more EY Temp alarms. One TCSY Chiller Flow alarm.