aaron.viets@LIGO.ORG - posted 08:42, Friday 06 January 2017 (33021)
New GDS filters for LHO post winter break
I have produced new GDS filters that incorporate the recent changes in the front-end calibration model, including the updated L2/L3 crossover. The filters can be found in the calibration SVN at this location:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/GDSFilters/H1GDS_1167602808.npz

For information on the changes in the calibration model, see these aLOGs:
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=33004
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=32933
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=32907

The filters were produced using this Matlab script in SVN revision 4095:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/Scripts/TDfilters/H1_run_td_filters_1167602808.m

The parameters files used (all in revision 4095) were:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/Common/params/IFOindepParams.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/params/H1params.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/params/2017-01-03/H1params_2017-01-03.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/params/H1_TDparams_1167602808.conf
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/Scripts/CAL_EPICS/D20170103_H1_CAL_EPICS_VALUES.m

Several plots are attached. The first two (png files) are spectrum comparisons between GDS and CALCS at GPS time 1167559872 (Jan 04, 2017, 10:10 UTC). Kappas were applied in making the GDS spectrum, using the EPICS from the filters file (the EPICS in the frames at this time are incorrect). The last plot contains a time series of the kappas computed by GDS and CALCS. Note that they do not agree. This is expected, as the EPICS were not updated in the front end.
Images attached to this report
Non-image files attached to this report
Displaying report 1-1 of 1.