Displaying report 1-1 of 1.
Reports until 08:36, Friday 06 January 2017
H1 INJ (CDS)
james.batch@LIGO.ORG - posted 08:36, Friday 06 January 2017 (33022)
Update software on h1hwinj1, restart psinject
WP 6416

The lalapps_Makefakedata_v4 binary was rebuilt to correct a leap second issue.  Rebuild procedure followed what was done at Livingston documented in FRS ticket 7014.  Monit was used to stop psinject, the new binary moved into place, and Monit was used to restart psinject.  Examination of running processes on h1hwinj showed the processes being stopped, and new processes being started after the restart.

Perhaps someone from the injection group could take a look to see that all is working as it should?