Displaying report 1-1 of 1.
Reports until 10:30, Saturday 07 January 2017
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 10:30, Saturday 07 January 2017 - last comment - 13:58, Monday 09 January 2017(33070)
IP5 Channel A Dead

(Chandra, Gerardo)

Remote logged in to find out status of IP5.  We lost one channel on IP5 at around 13:02 utc, the other channel still up.

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 10:35, Saturday 07 January 2017 (33071)VE

Attached is the pressure change due to loss of channel A.  Included are some channels from both Mid stations.

Images attached to this comment
chandra.romel@LIGO.ORG - 10:39, Saturday 07 January 2017 (33072)

We'll replace power supply Monday.

chandra.romel@LIGO.ORG - 13:58, Monday 09 January 2017 (33110)

One channel out on IP5 at corner has an affect on pressure 2.5 miles away (EY only).

Images attached to this comment