Displaying report 1-1 of 1.
Reports until 11:55, Wednesday 11 January 2017
H1 GRD (CAL)
thomas.shaffer@LIGO.ORG - posted 11:55, Wednesday 11 January 2017 (33150)
Added test to DIAG_MAIN for PCAL RX PD

The test takes an average of the last 120s of H1:CAL-PCAL(X/Y)_RX_PD_OUTPUT and compares it to nominal values that I found by taking many different averages over times without clipping. If the percent difference is greater than 1% it will notify.