Displaying report 1-1 of 1.
Reports until 16:20, Wednesday 11 January 2017
LHO General
patrick.thomas@LIGO.ORG - posted 16:20, Wednesday 11 January 2017 - last comment - 16:29, Wednesday 11 January 2017(33162)
Ops Day Shift Summary
TITLE: 01/12 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 67.1386Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Just made it back to observing. Lockloss likely from snow removal at end X ringing up BRS X.
LOG:
15:46 UTC John starting clearing snow by CP1
16:13 UTC Starting initial alignment
16:20 UTC Terra called from LLO to ask about our state. They will probably start a test.
16:36 UTC John at end Y clearing snow
16:46 UTC Krishna turning sensor correction at end Y off
16:52 UTC Krishna turning sensor correction at end Y back on
16:58 UTC May have accidently moved PR2 instead of BS during MICH_DARK_LOCKED. Trended back and changed pitch back to previous value. Went back to redo PRM_ALIGN.
17:01 UTC Accidently selected INPUT_ALIGN_OFFLOADED instead of PRM_ALIGN_OFFLOADED. Reselected PRM_ALIGN.
17:04 UTC Karen to warehouse
17:15 UTC Initial alignment complete
17:28 UTC John done clearing snow at end Y, working way back to corner
17:34 UTC Sensor correction had not actually been turned back on at end Y. Reselecting guardian state turned it on.
17:45 UTC Lockloss at INCREASE_POWER. HAM6 ISI tripped.
17:52 UTC Karen out of warehouse
18:07 UTC Lockloss at INCREASE_POWER. HAM6 ISI tripped.
18:20 UTC Gerardo to end Y to check on IP controller. Not going into VEA. Not changing BRS.
18:42 UTC Damped PI mode 27
18:46 UTC NLN
18:50 UTC Changed H1:SYS-MOTION_C_PICO_D_CURRENT_ENABLE from Enabled to Disabled. Observing.
19:02 UTC GRB. LLO is down. Called LLO control room. Joe says he did not receive alert. LLO currently down due to wind.
19:19 UTC Damped PI modes 27 and 28
19:22 UTC Kyle to mid Y to take pictures
19:26 UTC Damped PI mode 27. Had to change phase.
19:34 UTC GRB. LLO is still down.
19:49 UTC Chandra running down Y arm
19:52 UTC Ran passive a2l check: /opt/rtcds/userapps/release/isc/common/scripts/decoup/DARM_a2l_passive.xml. Looks fine.
20:08 UTC Greg to warehouse
20:19 URC Greg back from warehouse
20:20 UTC Kyle back from mid Y
20:32 UTC Joe to mid Y and end Y to shovel snow
21:25 UTC Bubba starting clearing snow on X arm
21:36 UTC Joe back from mid Y
21:38 UTC Damped PI mode 28
21:50 UTC Gerardo, Filiberto and Marc starting WP 6430
22:23 UTC Out of observing for Sheila to test affect on DARM of closing beam diverter
22:37 UTC Sheila done. Back to observing.
22:58 UTC Gerardo, Filiberto and Marc done
23:08 UTC Lock loss. BRS X in fault. Bubba at end X clearing snow with front end loader close to building.
23:15 UTC Changed ISI Config at end X to BLEND_Quite_250_SC_None.
23:25 UTC Bubba on the way back from end X
23:26 UTC John to mid X
23:46 UTC Changed ISI Config at end X back to BLEND_QUITE_250_SC_BRS
00:05 UTC Corey reports front end loader is back at corner station
00:09 UTC Krishna rerequested ISI Config at end X to BLEND_QUITE_250_SC_BRS
00:14 UTC Observing
Comments related to this report
patrick.thomas@LIGO.ORG - 16:29, Wednesday 11 January 2017 (33163)
00:28 UTC Diag reset H1IOPASC0 to clear timing error.
Displaying report 1-1 of 1.