SR3 Oplev Laser Power Increased (WP 6433)

As noted here, the SR3 oplev began glitching at around the same time H1 experienced a large range drop.  While the glitching is unlikely to be the cause of the range drop (no oplev damping on SR3), and Keita's request I have attempted to address the glitching.  As soon as H1 lost lock, I increased the laser power; the voltage that monitors the laser diode current increased from 0.934 mV to 0.940 mV.  This is the max for this laser, so if this does not alleviate the glitching I will try lowering the laser power.  If this does not work then a laser swap will be necessary.  I will leave WP 6433 open until it is known whether or not the laser power increase has alleviated the laser glitching.

Comments related to this report
jason.oberling@LIGO.ORG - 14:06, Friday 13 January 2017 (33237)

After a couple 3.5  hours it seems as though the power adjustment cleared the glitching.  Here is a link the SR3 summary pages; I've also attached the 2 relevant graphs to this alog.  The first attachment is a time series of the oplev SUM, where the glitching is clearly visible, as is my adjustment and the following cessation of the glitching.  The second attachment is a spectrogram of the SUM signal, normalized relative to the median.  Here it the start and end of the glitching can be clearly seen.  I will continue to monitor this over the weekend, but initially it looks like the laser power adjustment cleared the glitching for now.