Reports until 00:10, Tuesday 17 January 2017
LHO General
jeffrey.bartlett@LIGO.ORG - posted 00:10, Tuesday 17 January 2017 (33354)
Ops Evening Shift Summary
Ops Shift Log: 01/16/2017, Evening Shift 00:00 – 08:00 (16:00 - 00:00) Time - UTC (PT)
State of H1: IFO is unlocked due to PSL trip. Working on relocking
Intent Bit: Commissioning/Locking
Support: Jason, Dave B. 
Incoming Operator: Travis

Shift Summary:Lost lock due to PSL Head Flow sensor error. Jason recovered the PSL. Reset the Noise Eater and the X-Arm Fiber Polarization. Tried relocking and could not get either arm to lock green. Ran Green Arm Initial Alignment and restarted locking. Locking appeared to be working and was at DRMI-1F when Travis came in.

Activity Log: Time - UTC (PT)

00:00 (16:00) Take over from Patrick
00:21 (16:21) Set intent bit to Observing      
00:36 (16:36) Intent bit Commissioning, – VM 4735 Hz ringing up
01:04 (17:04) Cleared SDF difference (aLOG #33351) and set intent bit to Observing
01:14 (17:14) PI Modes 26 & 9 ringing up
01:26 (17:26) Set intent bit to Commissioning while suppressing PI Modes
01:47 (17:47) Finally got the PI modes to come down
01:47 (17:47) Set intent bit to Observing
06:15 (22:15) Lockloss due to PSL Trip – Head 1-4 Flow Sensor Error
07:14 (23:14) Start relocking
08:00 (00:00) Turn over to Travis