Reports until 06:25, Tuesday 17 January 2017
H1 General
travis.sadecki@LIGO.ORG - posted 06:25, Tuesday 17 January 2017 - last comment - 08:06, Tuesday 17 January 2017(33361)
Unable to get IMC to lock and Dataviewer issues

The IMC hasn't locked since the lockloss.  While following the troubleshooting Wiki instructions, I attempted to use Dataviewer to look at trends of various IMC related channels to no avail (see screenshot of error) no matter which data rate setting I chose.  With no data to point me to what is wrong, I cleared the IMC WFS as a hail mary.  This didn't help.  I'm not sure what to do next here.

Images attached to this report
Comments related to this report
travis.sadecki@LIGO.ORG - 06:45, Tuesday 17 January 2017 (33362)

Using TimeMachine as a last resort, I also set the IMC PZTs back to values from a previous lock stretch 12 hours ago.  This also did not help.

travis.sadecki@LIGO.ORG - 07:07, Tuesday 17 January 2017 (33363)

Turns out this was due to some MC2 OSEMs being railed because I apparently forgot to take ISC_LOCK to DOWN before going back to INITIAL_ALIGNMENT.  IMC is locked again now.

james.batch@LIGO.ORG - 08:06, Tuesday 17 January 2017 (33366)

Dataviewer has been fixed. The operating system type wasn't determined properly, so paths to programs were incorrect.  Operator should log out of the workstation and log back in.