Reports until 17:39, Tuesday 17 January 2017
H1 SUS (DetChar, ISC, OpsInfo)
jeffrey.kissel@LIGO.ORG - posted 17:39, Tuesday 17 January 2017 (33395)
Transfer Function Assessment of ITMs: ITMX R0 and ITMY M0 Chains Definitely Rubbing, Offsets Help
J. Kissel

I've run a full suite of top-to-top transfer functions for all four chains of the ITM quads in order to make a complete and traditional assessment of rubbing, given the latest suspicions of it impacting the IFO performance (see LHO aLOG 33380). 

Though I have not yet processed all the data, I can confirm that ITMX R0 and ITMY M0 chains are definitely rubbing with out the recently applied large vertical offsets. With the offsets applied, ITMY's M0 chain rubbing is alleviated. However, the case is not so clear for ITMX's R0 chain. I attach several preliminary plots to whet your appetite. Here "Old Meas" is the last data set we have for the ITMs which were after the vent in 2014. More details to come tomorrow.

Now -- both the FMCS crew is playing with the LVEA temperature (see LHO aLOG 33373), and the observatory is expecting above-freezing temperature for the first time in weeks in the next few days. So, I expect that the rubbing situation will be totally different every 8 hours or so.

So I'll process this data to it's fullest tomorrow, just to grease the analysis script wheels, but I wouldn't get one's hopes up that (a) I'll have any perfect solutions, or (b) that that solution will be right in the next 24 hours. Also, we must remember that IFO problems come in sevens, so even if we do alleviate the rubbing...

--------
The data lives here:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGM0/Data/
2017-01-17_2134_H1SUSITMX_M0_WhiteNoise_L_0p02to50Hz.xml << No extra offsets and Alignment Sliders ON (Nominal)
2017-01-17_2134_H1SUSITMX_M0_WhiteNoise_P_0p02to50Hz.xml Initial Assessment: CLEAR OF RUBBING.
2017-01-17_2134_H1SUSITMX_M0_WhiteNoise_R_0p02to50Hz.xml
2017-01-17_2134_H1SUSITMX_M0_WhiteNoise_T_0p02to50Hz.xml
2017-01-17_2134_H1SUSITMX_M0_WhiteNoise_V_0p02to50Hz.xml
2017-01-17_2134_H1SUSITMX_M0_WhiteNoise_Y_0p02to50Hz.xml

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Data/
2017-01-17_1931_H1SUSITMX_R0_WhiteNoise_L_0p02to50Hz.xml << Extra V & P Offsets w/ Alignment Sliders ON
2017-01-17_1931_H1SUSITMX_R0_WhiteNoise_P_0p02to50Hz.xml Initial Assessment: Unclear if still rubbing.
2017-01-17_1931_H1SUSITMX_R0_WhiteNoise_R_0p02to50Hz.xml
2017-01-17_1931_H1SUSITMX_R0_WhiteNoise_T_0p02to50Hz.xml
2017-01-17_1931_H1SUSITMX_R0_WhiteNoise_V_0p02to50Hz.xml
2017-01-17_1931_H1SUSITMX_R0_WhiteNoise_Y_0p02to50Hz.xml

2017-01-17_2000_H1SUSITMX_R0_WhiteNoise_L_0p02to50Hz.xml << NO Extra V & P Offsets w/ Alignment Sliders ON
2017-01-17_2000_H1SUSITMX_R0_WhiteNoise_P_0p02to50Hz.xml Initial Assessment: Unclear if rubbing.
2017-01-17_2000_H1SUSITMX_R0_WhiteNoise_R_0p02to50Hz.xml
2017-01-17_2000_H1SUSITMX_R0_WhiteNoise_T_0p02to50Hz.xml
2017-01-17_2000_H1SUSITMX_R0_WhiteNoise_V_0p02to50Hz.xml
2017-01-17_2000_H1SUSITMX_R0_WhiteNoise_Y_0p02to50Hz.xml

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGM0/Data/
2017-01-17_2031_H1SUSITMY_M0_Mono_WhiteNoise_L_0p02to50Hz.xml << Extra V Offsets ON w/ alignment sliders ON
2017-01-17_2031_H1SUSITMY_M0_Mono_WhiteNoise_P_0p02to50Hz.xml Initial Assessment: CLEAR OF RUBBING, Extra Offsets GOOD.
2017-01-17_2031_H1SUSITMY_M0_Mono_WhiteNoise_R_0p02to50Hz.xml
2017-01-17_2031_H1SUSITMY_M0_Mono_WhiteNoise_T_0p02to50Hz.xml
2017-01-17_2031_H1SUSITMY_M0_Mono_WhiteNoise_V_0p02to50Hz.xml
2017-01-17_2031_H1SUSITMY_M0_Mono_WhiteNoise_Y_0p02to50Hz.xml

2017-01-17_2131_H1SUSITMY_M0_Mono_WhiteNoise_L_0p02to50Hz.xml << NO Extra V Offsets w/ alignment sliders ON
2017-01-17_2131_H1SUSITMY_M0_Mono_WhiteNoise_P_0p02to50Hz.xml Initial Assessment: DEFINITELY RUBBING. Needs Offsets
2017-01-17_2131_H1SUSITMY_M0_Mono_WhiteNoise_R_0p02to50Hz.xml
2017-01-17_2131_H1SUSITMY_M0_Mono_WhiteNoise_T_0p02to50Hz.xml
2017-01-17_2131_H1SUSITMY_M0_Mono_WhiteNoise_V_0p02to50Hz.xml
2017-01-17_2131_H1SUSITMY_M0_Mono_WhiteNoise_Y_0p02to50Hz.xml

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Data/
2017-01-17_2038_H1SUSITMY_R0_L_WhiteNoise_0p02to50Hz.xml << No extra offsets, alignment sliders ON (Nominal)
2017-01-17_2038_H1SUSITMY_R0_P_WhiteNoise_0p02to50Hz.xml Initial Assessment: CLEAR OF RUBBING.
2017-01-17_2038_H1SUSITMY_R0_R_WhiteNoise_0p02to50Hz.xml
2017-01-17_2038_H1SUSITMY_R0_T_WhiteNoise_0p02to50Hz.xml
2017-01-17_2038_H1SUSITMY_R0_V_WhiteNoise_0p02to50Hz.xml
2017-01-17_2038_H1SUSITMY_R0_Y_WhiteNoise_0p02to50Hz.xml
Images attached to this report