CP3, CP4 Autofill 2017_01_20
Starting CP3 fill. LLCV enabled. LLCV set to manual control. LLCV set to 50% open. Fill completed in 2179 seconds. TC B did not register fill. LLCV set back to 15.0% open.
Starting CP4 fill. LLCV enabled. LLCV set to manual control. LLCV set to 70% open. Fill not completed after 3600 seconds. LLCV set back to 34.0% open.
Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 13:18, Friday 20 January 2017 (33461)

Increased CP4 LLCV from 34% to 36% open. Auto fill did not complete - timed out after 60 min. I did a manual fill from control room @ 1:11pm local at 70% open. Took an additional 6 min. (+ 60 min from autofill).

Increased CP3 LLCV from 15% to 17% open.

Note that CP3 exhaust line is more insulated with snow/ice than CP4.