cheryl.vorvick@LIGO.ORG - posted 21:58, Saturday 21 January 2017 (33495)
ETMY violin mode 3 - improved damping with -60 deg phase

Plot attached shows the mode damping much faster after I engaged the -60 deg phase filter.  I had increased the gain (-20 to -50) before the phase change with no positive results to damping, which led me to trying a phase change.  Doubt I'll get far enough to try again and confirm in a second lock (M8.0 earthquake).