Reports until 08:16, Sunday 22 January 2017
LHO General
patrick.thomas@LIGO.ORG - posted 08:16, Sunday 22 January 2017 (33502)
Ops Owl Shift Summary
TITLE: 01/22 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ed
SHIFT SUMMARY: Ran an initial alignment after the lock loss from the earthquake and made it back to observing. Lost lock for an unknown reason and have struggled to relock since. I have resisted doing another initial alignment, but it may be necessary.
LOG:

Cheryl took ISI_CONFIG to WINDY_NO_BRSX because it appeared that BRSX was starting to ring up.

08:45 UTC BRSX appears to be stable. Took ISI_CONFIG to WINDY.
08:48 UTC Starting attempt to lock arms on green.
09:30 UTC Locked on arms green. Needed to move TMSX a significant amount in yaw.
09:35 UTC Starting initial alignment.
10:03 UTC Going to PRM_ALIGN unlocked the IMC. FSS is oscillating. Turning the FSS autolock off and back on fixed it.
10:16 UTC MICH not staying locked even after going to DOWN and back to MICH_DARK_LOCKED repeatedly. Aligned the BS before it could unlock.
10:28 UTC Initial alignment done.
10:39 UTC ISI HAM6 WD tripped in DRMI_ASC_OFFLOAD. Reset it.
10:45 UTC Lock loss from ENGAGE_REFL_POP_WFS. Purple and gray striptool traces dropping and oscillating before.
11:29 UTC NLN
11:36 UTC Running a2l
11:42 UTC Observing
12:53 UTC Clicked start on RF noise monitor on nuc5. For some reason it was stopped.
14:29 UTC Lock loss. HAM6 ISI tripped.
15:21 UTC Lock loss switching to QPDs.
15:26 UTC Moved TMSX to increase x arm green power.
15:47 UTC Lockloss sitting at REDUCE_CARM_OFFSET.