Laser Status:
SysStat is good
Front End Power is 34.06W (should be around 30 W)
Front End Watch is GREEN
HPO Watch is GREEN
PMC:
It has been locked 2.0 days, 17.0 hr 57.0 minutes (should be days/weeks)
Reflected power is 13.65Watts and PowerSum = 77.54Watts.
FSS:
It has been locked for 0.0 days 0.0 hr and 11.0 min (should be days/weeks)
TPD[V] = 2.413V (min 0.9V)
ISS:
The diffracted power is around 3.6% (should be 3-5%)
Last saturation event was 0.0 days 0.0 hours and 41.0 minutes ago (should be days/weeks)
Possible Issues:
(Be sure to look into these, as they will not be printed in the report)
PMC reflected power is high
Note: See attached screenshot of the PMC Refl power for the past month. It has been reported as being high for the past 2 weeks (see Corey's aLog 33378). Is this due to some adjustment by the PSL team and we should update our weekly script with a higher nominal value, or is this a real issue?
This completes FAMIS 7422.
Updated the script with the new PMC values.