Displaying report 1-1 of 1.
Reports until 09:03, Monday 30 January 2017
H1 General
travis.sadecki@LIGO.ORG - posted 09:03, Monday 30 January 2017 - last comment - 10:28, Monday 30 January 2017(33730)
Observing at 17:03 UTC

No issues relocking.

Comments related to this report
travis.sadecki@LIGO.ORG - 09:10, Monday 30 January 2017 (33731)

Out of Observing from 17:08-17:09 UTC to turn off FM9 filter for 4.7kHz violin mode. 

keita.kawabe@LIGO.ORG - 10:28, Monday 30 January 2017 (33735)

Guardian has been reverting FM9 back ON for EY 4.7k violin damping repeatedly, confusing operators.

I changed ISC_GEN_STATES.py line 597 so FM9 doesn't keep coming back.

Old:  ey_mode[10].only_on('INPUT', 'FM4', 'FM9', 'FM10',  'OUTPUT', 'DECIMATION')

New: ey_mode[10].only_on('INPUT', 'FM4', 'FM10',  'OUTPUT', 'DECIMATION')

Next time H1 loses lock, ISC_LOCK guardian should be reloaded.