Displaying report 1-1 of 1.
Reports until 00:00, Tuesday 31 January 2017
H1 SEI
jim.warner@LIGO.ORG - posted 00:00, Tuesday 31 January 2017 (33741)
Eq Report

4.0M  Port Hardy Canada

Was it reported by Terramon, USGS, SEISMON? Yes, Yes, No

Magnitude (according to Terramon, USGS, SEISMON): 4.4,4.0, NA

Location: 

Time
Location
49.957°N 127.814°W
Depth
11.0 km

Starting time of event (ie. when BLRMS started to increase on DMT on the wall): ~0:00 UTC

Lock status? Stayed locked even though .03-.1hz blrms got to ~.7 microns

EQ reported by Terramon BEFORE it actually arrived? I noticed asc, imc doing eq band stuff before even USGS listed it. Attached plots show pitch and yaw asc trends from 10-15 (left side of each screen) minutes before and 10minutes during. Look at the ITMY STS blrms in the lower left of each image to get a feel for what the ground was doing.

Images attached to this report
Displaying report 1-1 of 1.