Reports until 08:10, Tuesday 31 January 2017
H1 General
cheryl.vorvick@LIGO.ORG - posted 08:10, Tuesday 31 January 2017 - last comment - 09:19, Tuesday 31 January 2017(33751)
Ops Owl Summary:

TITLE: 01/31 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Corey
SHIFT SUMMARY: locked entire time
LOG:


 

Comments related to this report
cheryl.vorvick@LIGO.ORG - 09:19, Tuesday 31 January 2017 (33756)

Addition:

  • I restarted Verbal Alarms, it emails TJ, so talked to him on the way out of the building so he knows
  • after Jim rebooted and StripTools were no longer flatlined, PI mode 28 had run up, what's interesting is that it wasn't getting worse, but it was high, so I changed the gain from -5000 to +5000 and the mode RMS came back down
  • after going out of Observe, I ran a test on ITMX Roll Mode - increased gain to +100, switched on -30deg phase, indication was that this in the direction of improving the damping, but no time to explore other options