cheryl.vorvick@LIGO.ORG - posted 08:10, Tuesday 31 January 2017 - last comment - 09:19, Tuesday 31 January 2017(33751)
Ops Owl Summary:
TITLE: 01/31 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC STATE of H1: Commissioning INCOMING OPERATOR: Corey SHIFT SUMMARY: locked entire time LOG:
snow removal
boot machine died, all striptool signals flatlined, Jim rebooted, H1 stayed locked
H1 locked in Observe
Comments related to this report
cheryl.vorvick@LIGO.ORG - 09:19, Tuesday 31 January 2017 (33756)
I restarted Verbal Alarms, it emails TJ, so talked to him on the way out of the building so he knows
after Jim rebooted and StripTools were no longer flatlined, PI mode 28 had run up, what's interesting is that it wasn't getting worse, but it was high, so I changed the gain from -5000 to +5000 and the mode RMS came back down
after going out of Observe, I ran a test on ITMX Roll Mode - increased gain to +100, switched on -30deg phase, indication was that this in the direction of improving the damping, but no time to explore other options
Addition: