cheryl.vorvick@LIGO.ORG - posted 07:27, Wednesday 01 February 2017 (33795)
PI modes 27, 28, and 26 rang up in that order
PI mode 27 rang up first, but I had trouble damping it, followed Terra's instructions, changed phase, lowered the gain, changed the phase on the damping fitler
mode 27 leveled off
in the mean time mode 28 rang up, followed Terra's instructions, changed phase, changed the gain, changed the phase on the damping fitler
mode 28 leveled off
mode 26 rang up
Terra called, identified that the drive to ETMY was saturating
I lowered mode 27's gain even more (was 7000, then 3500, now 2000)
reset damping filter phases with SDF
it took a few minutes, but all modes damped
H1 into Observe
the range drop before going to Observe is due to PI modes, tagging for DetChar