2017-02-06 08:44:17.375795
There are 5 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF Y/V = -0.439 [V]
ETMY T240 3 DOF Z/W = 0.417 [V]
ITMY T240 3 DOF X/U = -0.328 [V]
ITMY T240 3 DOF Z/W = -1.161 [V]
BS T240 1 DOF Z/W = 0.319 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.16 [V]
ETMX T240 1 DOF Y/V = 0.112 [V]
ETMX T240 1 DOF Z/W = 0.203 [V]
ETMX T240 2 DOF X/U = -0.282 [V]
ETMX T240 2 DOF Z/W = -0.008 [V]
ETMX T240 3 DOF X/U = 0.13 [V]
ETMX T240 3 DOF Y/V = 0.107 [V]
ETMX T240 3 DOF Z/W = 0.099 [V]
ETMY T240 1 DOF X/U = 0.062 [V]
ETMY T240 1 DOF Y/V = 0.176 [V]
ETMY T240 1 DOF Z/W = -0.077 [V]
ETMY T240 2 DOF X/U = 0.261 [V]
ETMY T240 2 DOF Y/V = -0.122 [V]
ETMY T240 2 DOF Z/W = 0.043 [V]
ETMY T240 3 DOF X/U = -0.084 [V]
ETMY T240 3 DOF Y/V = 0.068 [V]
ITMX T240 1 DOF X/U = -0.134 [V]
ITMX T240 1 DOF Y/V = -0.101 [V]
ITMX T240 1 DOF Z/W = -0.027 [V]
ITMX T240 2 DOF X/U = -0.041 [V]
ITMX T240 2 DOF Y/V = -0.038 [V]
ITMX T240 2 DOF Z/W = -0.04 [V]
ITMX T240 3 DOF X/U = -0.061 [V]
ITMX T240 3 DOF Y/V = -0.012 [V]
ITMX T240 3 DOF Z/W = 0.004 [V]
ITMY T240 1 DOF X/U = 0.12 [V]
ITMY T240 1 DOF Y/V = 0.072 [V]
ITMY T240 1 DOF Z/W = 0.068 [V]
ITMY T240 2 DOF X/U = 0.071 [V]
ITMY T240 2 DOF Y/V = 0.196 [V]
ITMY T240 2 DOF Z/W = 0.17 [V]
ITMY T240 3 DOF Y/V = 0.17 [V]
BS T240 1 DOF X/U = -0.042 [V]
BS T240 1 DOF Y/V = 0.054 [V]
BS T240 2 DOF X/U = 0.152 [V]
BS T240 2 DOF Y/V = 0.293 [V]
BS T240 2 DOF Z/W = 0.127 [V]
BS T240 3 DOF X/U = 0.142 [V]
BS T240 3 DOF Y/V = 0.018 [V]
BS T240 3 DOF Z/W = -0.003 [V]
2017-02-06 08:52:25.352810
STS A DOF X/U = -0.537 [V]
STS A DOF Y/V = 0.097 [V]
STS A DOF Z/W = -0.56 [V]
STS B DOF X/U = 0.564 [V]
STS B DOF Y/V = 0.29 [V]
STS B DOF Z/W = -0.225 [V]
STS C DOF X/U = -0.0 [V]
STS C DOF Y/V = -0.0 [V]
STS C DOF Z/W = -0.0 [V]
STS EX DOF X/U = -0.03 [V]
STS EX DOF Y/V = 0.498 [V]
STS EX DOF Z/W = 0.095 [V]
STS EY DOF X/U = 0.188 [V]
STS EY DOF Y/V = 0.075 [V]
STS EY DOF Z/W = 0.447 [V]