Evan G., Joe B., Jeff K.
Joe B. pointed out that there is an uncompensated ~5.215 kHz pole in the ESD output filter bank because our filter design zpk([3229.1150], [], -1, "n") results in Foton providing a pole to compensate the zero at high frequency. So the actual installed filter is zpk([3229.115],[5215.189175235227],0.9999999999999999,"n").
The ~3.229 kHz zero compensates for a pole in the analog electronics. Unfortunately, the ~5.215 kHz pole is uncompensated. Attached is a Matlab figure showing the effects from 1 Hz to 10 kHz. The band of most interest to us is <200 Hz since above 200 Hz the actuation is sufficiently rolled off that it does not contribute to the response of the interferometer.
Below 200 Hz, there is very small residual magnitude error. Phase, however, is incorrect by ~1.1 degrees at 100 Hz. The equivalent delay is ~30 usec. This could explain part of the unknown actuation delay, which--for LHO--is 61 usec.