Reports until 16:29, Tuesday 07 February 2017
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 16:29, Tuesday 07 February 2017 (33983)
CDS maintenance summary, Tuesday 7th February 2017

Python standard environment work

Jim

HVAC networking between OSB and LSB

Carlos, Jim, Apollo

Installed a new HVAC unit on the network link between OSB and LSB

Remove timing status of DTS fanout from Beckhoff SDF

Dave

Modifed the ecatc1plc1 observe.snap to make IFO observation mode agnostic to DTS status.

Patch and reboot h1dmtlogin

Dave:

The debian 2FA authentication machine for DMT was patched. It had been running for 245 days, so it was rebooted. It came back quickly, indicating an FSCK completed quickly or was not ran.

Note to control room, the EPICS readback of H1 range goes to -1.0 when h1dmtlogin is rebooted, it acts as the proxy server for this GDS data.

Conlog channel lists

Patrick

Generation of the channel list for conlog was improved.