cheryl.vorvick@LIGO.ORG - posted 16:05, Saturday 11 February 2017 - last comment - 18:06, Saturday 11 February 2017(34062)
Day Shift Summary:

TITLE: 02/11 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 71Mpc
INCOMING OPERATOR: Ed
SHIFT SUMMARY: locked entire shift, tried some damping on mode 22 and mode 23, and tried to damp mode 26
LOG:

Comments related to this report
cheryl.vorvick@LIGO.ORG - 18:06, Saturday 11 February 2017 (34067)

more about modes 22 and 23:

  • tried gain of 1000 on mode 22, it rang up, set it back to zero
  • then started at gain of -1, and tried -2 on both mode 22 and 23
  • changed phases, negative was better than positive
  • then turned mode 23 off and focused on mode 22 (it was larger / higher)
  • tried combinations and eventually after it damped I turned it off and left it off
  • Terra called in response to a voicemail left earlier
  • she advised raising the gain on mode 26 until PI Damp was hundereds to thousands of counts, but not so high that it's 10000+ counts
  • I turned the gain on mode 26 to -170000, and got a couple hundred counts on PI Damp, and left it at that gain