Displaying report 1-1 of 1.
Reports until 17:30, Wednesday 11 July 2012
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 17:30, Wednesday 11 July 2012 (3409)
HSTS MC1 Open Light Values

	HSTS MC1 has been moved to the testing bench and cabled to the test stand. The offsets and gains have been entered into the MEDM screens and the OSEMs have been positioned to 50% light. We will recheck and adjust the 50% light positions in the morning, if necessary. This suspension should be ready for Phase 1 testing. 
	
 M1 BOSEMs
 T1 S/N 578 OL = 25960.0 Offset = -12980 Gain = 1.156
 T2 S/N 436 OL = 29277.9 Offset = -14639 Gain = 1.025
 T3 S/N 440 OL = 27858.1 Offset = -13929 Gain = 1.077
 LF S/N 433 OL = 27758.7 Offset = -13879 Gain = 1.081
 RT S/N 424 OL = 24529.4 Offset = -12265 Gain = 1.223
 SD S/N 658 OL = 25139.5 Offset = -12570 Gain = 1.193

 M2 AOSEM
 UL S/N 453 OL = 27359.6 Offset = -13680 Gain = 1.097
 LL S/N 320 OL = 24780.7 Offset = -12390 Gain = 1.211
 UR S/N 228 OL = 25117.9 Offset = -12559 Gain = 1.194
 LR S/N 438 OL = 25521.6 Offset = -12761 Gain = 1.175

 M3 AOSEM
 UL S/N 227 OL = 28354.2 Offset = -14177 Gain = 1.058
 LL S/N 353 OL = 26509.5 Offset = -13255 Gain = 1.132
 UR S/N 276 OL = 27920.9 Offset = -13960 Gain = 1.074
 LR S/N 299 OL = 28435.2 Offset = -14218 Gain = 1.055
  
Displaying report 1-1 of 1.