Reports until 10:37, Tuesday 14 February 2017
LHO VE
chandra.romel@LIGO.ORG - posted 10:37, Tuesday 14 February 2017 - last comment - 10:40, Tuesday 14 February 2017(34127)
Three vacuum gauges mysteriously turned off at EX

And now three cold cathode gauges turned off at EX:  PT523, PT524, PT510. I enabled the pirani interlocks and two came back instantly. Dave B. is going out to investigate. Robert is working at EX.

Pirani pressure plots attached.

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 10:40, Tuesday 14 February 2017 (34128)

Fire dept was out there too testing fire alarms. Should not affect vacuum rack but maybe a build up of static electricity??