Reports until 10:55, Tuesday 14 February 2017
H1 ISC
terra.hardwick@LIGO.ORG - posted 10:55, Tuesday 14 February 2017 - last comment - 19:17, Tuesday 14 February 2017(34129)
Mode 26 fixed

MODE 26 has been fixed: it has been raised due to an incorrect high pass placement implemented 2/10 when we were setting up new filters. I've fixed this and it should go back to normal amplitudes and damping gain needs. Thanks operators for alerting medealing with this.

(TRY QPD INP FILT #1 had accidentally been switched from a 14.8-15.8 kHz BP filter to a 32kHz high pass. I've reverted this. OMC DCPD INP FILT #3 still has its correct 31kHz high pass.)

Comments related to this report
sheila.dwyer@LIGO.ORG - 19:17, Tuesday 14 February 2017 (34156)

Sorry, probably my mistake.