Displaying report 1-1 of 1.
Reports until 11:42, Tuesday 14 February 2017
LHO VE
chandra.romel@LIGO.ORG - posted 11:42, Tuesday 14 February 2017 - last comment - 11:52, Tuesday 14 February 2017(34133)
CP1 electronic actuator flooded

Kyle found CP1 LLCV actuator flooded in his routine rounds to fix the leaky joints. Actuator was partially stroking during thawing and is now stuck at 100% open, so CP1 is currently overfilled. We're working on it.

Comments related to this report
chandra.romel@LIGO.ORG - 11:52, Tuesday 14 February 2017 (34134)

Fixed. Blown fuse.

Displaying report 1-1 of 1.