Displaying report 1-1 of 1.
Reports until 18:55, Tuesday 14 February 2017
H1 ISC (CDS, PSL)
sheila.dwyer@LIGO.ORG - posted 18:55, Tuesday 14 February 2017 - last comment - 12:45, Wednesday 15 March 2017(34154)
Installation of bullseye detector (mostly done)

Sheila, Jenne, Mark, Richard, Fil, Daniel

We made some progress on installing a prototype of the bullseye detector that Mark has been building in the PSL today. 

We will hopefully get the whitened signals into the ADC channels that are already set aside and connected to AS_D in the ASC model tomorow. 

Comments related to this report
richard.mccarthy@LIGO.ORG - 10:37, Wednesday 15 February 2017 (34174)ISC
Fil and Richard

Verified the cabling for this setup.  Out of the whitening was a 9pin ISC cable 250 which ran to ADC0 AA chassis in ISC-C1 port 7.  It was unplugged from that port and move to ADC5 AA chassis port6 channels 21-24.  We still need to verify operation.
sheila.dwyer@LIGO.ORG - 18:31, Thursday 16 February 2017 (34204)

Important note!  The segment numbers I wrote above are incorrect

This morning I checked the signals from the bullseye detector using a scope in the ISC rack, and saw that all 4 channels had a large oscialltion at 52kHz.  I got it off the table and Mark Richard and Fil spent some time in the EE shop, and saw that indeed, attaching a long cable to the detector made it oscillate.  Mark changed the 50 Ohm series resistors to 100Ohms, which fixed the problem.  While we were there Mark also confirmed with a laser pointer that the middle segment is on pin 2 of the connector. 

While the detector was in the shop, Vaishali and I went back to the rack and checked which pins on the input to the whitening chassis showed up as which segments in the digital system.  This was not as I had expected, the correct mapping is in this table: 

Head pins segment in AS_D
center 2+7 3
bottom 4+9 1
HAM1 side 3+8 2
anteroom side 1+6 4

Robert and I went back into the PSL and put the detecor back on the table, and removed the lens so that we now have close to equal amounts of power in the center of the bullseye and in the outer ring.  By the time we came out, the alignment seems to have shifted a little.  

Keita checked on the whitening, and it seems to be working OK.  We set dark offsets with the diode unplugged, one stage of whitening on and 24dB of whitening gain.  We didn't measure the dark noise, so if anyone gets a chance to go back in it would be good to both measure the dark noise and try to readjust the alignment. 

kiwamu.izumi@LIGO.ORG - 12:45, Wednesday 15 March 2017 (34849)

I went in to the PSL yesterday, the 14th, during the maintenance period as described in WP6522. I have done the following activities.

  • I realigned the beam by steering the mirror in front of the bullseye.
  • I uncoiled the 9 pin Dsub cable a bit and gave it an extra 1-meter slack.
  • I took some pictures. They can be found at ResourceSpace.

By the way, here is a picture of the bullseye setup.

Images attached to this comment
Displaying report 1-1 of 1.