Displaying report 1-1 of 1.
Reports until 17:52, Wednesday 01 March 2017
H1 ISC
jenne.driggers@LIGO.ORG - posted 17:52, Wednesday 01 March 2017 (34512)
Tested procedure for arm cavity scans, for absorption measurements

Aidan asked me to look at scanning the arm cavities immediately after a lockloss, so that we can look at the higher-order-mode spacing as a function of time as the interferometer cools off.  We hope to be able to infer from this the absorption in each of the individual arms, to help separate if there is anomalously high absorption in one of the arms and if so, which one. 

The procedure was basically identical to that of Kiwamu's back in 2014 at LLO (LLO alog 13768).  The general idea is to lock the arms on green and hold them steady with ALS, then put an offset in the ALS COMM to adjust the PSL frequency relative to the arm cavities. 

Since we do have the frequency difference discriminator (FDD) in the ALS COMM system, we can't scan more than 1.5 or 2 FSR in our nominal configuration.  During the commissioning period today, Sheila showed me how to bypass the FDD.  After she bypassed it, I was able to scan almost 10 FSR per arm.  The cold-cavity scan I took today was much too slow, so the data isn't particularly clean.  Also, I neglected to add a small misalignment to the input IR beam, which will help the higher order modes to resonate.  At the end of the commissioning window, we put the FDD back into the signal chain.

So, our plan for the next time we have a commissioning window, or perhaps just at the beginning of maintenece on Tuesday, is the following:

 

Non-image files attached to this report
Displaying report 1-1 of 1.