Reports until 05:53, Saturday 04 March 2017
H1 AOS (DetChar, PSL)
cheryl.vorvick@LIGO.ORG - posted 05:53, Saturday 04 March 2017 - last comment - 06:34, Saturday 04 March 2017(34571)
Temperature in PSL drops - noise on PMC Trans, MC2 Trans

Not sure it killed the last lock, but for sure it caused noise that the IMC sees, both times the temperature has dropped in the last 24 hours.

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 06:17, Saturday 04 March 2017 (34572)
  • Noise is clearly visible on the HAM2 ISS second loop qpd, and the X arm Trans A qpd.
  • Also, 11 hours ago when this happened, there was a realitively small increase in noise, and it seemed to recover, and then the noise got worse again, and H1 lost lock.
  • In this lock the small increase in noise has come and gone, and H1 just glittched in range down to about 10Mpc.
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 06:34, Saturday 04 March 2017 (34573)
  • taking a closer look at REFL_DC and the temperature, REFL recovers part or all of the way after the bursts of noise, at least in a time series, so lock loss may not be related
Images attached to this comment