TITLE: 03/05 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 63Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY:
H1 overnight issues now understood / corrected:
- timing error seen in VerbalAlarms - Dave's look showed no current error: alogs 34583 and 34587
- h1broadcast0 - stopped last night, power cycled this morning, OK now: alogs 34587 and 34588
- PSL temperature - makeup air reduced from 100% to 20%: alogs 34584 and 34586
Added -30deg phase to ITMX bounce (FM7) - can't find it in guardian, so SDF should be accepted when relocking
LOG:
- entry into the LVEA: 14:15UTC to 14:26UTC
- entry into the MSR: 14:45UTC to 14:50UTC