DMT monitors are back after Cheryl rebooted h1broadcast0. I verified that no full frames were lost from h1fw0 or h1fw1 overnight. We did lose HofT frames when the DMT broadcaster was down. Keith is testing redundant broadcasters at LLO to prevent a problem like this.
keith.thorne@LIGO.ORG - 14:59, Sunday 05 March 2017 (34598)
Redundant GDS broadcasting now working at LLO to one DMT machine. Need to install network switch(es), additional Ethernet cards for redundancy on the redundant DMT machines..
DMT monitors are back after Cheryl rebooted h1broadcast0. I verified that no full frames were lost from h1fw0 or h1fw1 overnight. We did lose HofT frames when the DMT broadcaster was down. Keith is testing redundant broadcasters at LLO to prevent a problem like this.