Reports until 12:10, Monday 06 March 2017
LHO VE
logbook/robot/script0.cds.ligo-wa.caltech.edu@LIGO.ORG - posted 12:10, Monday 06 March 2017 - last comment - 13:23, Monday 06 March 2017(34620)
CP3, CP4 Autofill 2017_03_06
Starting CP3 fill. LLCV enabled. LLCV set to manual control. LLCV set to 50% open. Fill completed in 2143 seconds. LLCV set back to 17.0% open.
Starting CP4 fill. LLCV enabled. LLCV set to manual control. LLCV set to 70% open. Fill completed in 1961 seconds. TC A did not register fill. LLCV set back to 39.0% open.
Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 13:23, Monday 06 March 2017 (34621)

Raised CP4 LLCV to 40% open and CP3 LLCV to 18% open.