Ops Owl Shift Transition

TITLE: 03/09 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC

STATE of H1: Observing at 61Mpc

OUTGOING OPERATOR: Ed

CURRENT ENVIRONMENT: Wind: 5mph Gusts, 4mph 5min avg Primary useism: 0.01 μm/s Secondary useism: 0.18 μm/s

QUICK SUMMARY: Spotted a bunch of EY CDS overview went red. The status reverted before I can identify which column it was complaining.

Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 00:38, Thursday 09 March 2017 (34691)

I attached a plot of H1IOPSUSEY status over the past 30 mins. I saw two columns went red on this one. The number read 6 and 512.

Images attached to this comment
david.barker@LIGO.ORG - 10:14, Thursday 09 March 2017 (34700)

Note to operators: remember that h1susex and h1susey are running the newer, faster computers to keep processing time to within the 60uS limit. This system has a feature, occassionally the IOP runs long for a single cycle resulting in a latched TIM, ADC error on the IOP, and sometimes an IPC error which propagates to the SUS models, SEI models and ISC models at the end station. A cronjob running every minute at the zero second mark clears these latched errors.

As an example of the frequency of these glitches, over the past 7 days, EX has glitched 61 times and EY 38 times (once every 2 and 4 hours respectively).