Seismometer Mass Position Check - Monthly FAMIS #6084

Here's a list of how they're doing just in case you care:
STS A DOF X/U = -0.483 [V]
STS A DOF Y/V = 0.197 [V]
STS A DOF Z/W = -0.661 [V]
STS B DOF X/U = 0.54 [V]
STS B DOF Y/V = 0.305 [V]
STS B DOF Z/W = -0.245 [V]
STS C DOF X/U = 0.391 [V]
STS C DOF Y/V = 0.729 [V]
STS C DOF Z/W = -0.245 [V]
STS EX DOF X/U = 0.079 [V]
STS EX DOF Y/V = 0.576 [V]
STS EX DOF Z/W = 0.087 [V]
STS EY DOF X/U = 0.129 [V]
STS EY DOF Y/V = 0.096 [V]
STS EY DOF Z/W = 0.463 [V]
 

2017-03-09 20:17:42.356342


There are 6 T240 proof masses out of range ( > 0.3
ETMX T240 2 DOF X/U = -0.47 [V]
ETMX T240 2 DOF Y/V = -0.574 [V]
ETMY T240 3 DOF Z/W = 0.373 [V]
ITMY T240 3 DOF X/U = -0.41 [V]
ITMY T240 3 DOF Z/W = -1.306 [V]
BS T240 1 DOF Z/W = 0.302 [V]


All other proof masses are within range ( < 0.3 [V
ETMX T240 1 DOF X/U = 0.092 [V]
ETMX T240 1 DOF Y/V = 0.085 [V]
ETMX T240 1 DOF Z/W = 0.184 [V]
ETMX T240 2 DOF Z/W = -0.203 [V]
ETMX T240 3 DOF X/U = 0.116 [V]
ETMX T240 3 DOF Y/V = 0.031 [V]
ETMX T240 3 DOF Z/W = 0.07 [V]
ETMY T240 1 DOF X/U = 0.018 [V]
ETMY T240 1 DOF Y/V = 0.127 [V]
ETMY T240 1 DOF Z/W = -0.166 [V]
ETMY T240 2 DOF X/U = 0.234 [V]
ETMY T240 2 DOF Y/V = -0.191 [V]
ETMY T240 2 DOF Z/W = 0.029 [V]
ETMY T240 3 DOF X/U = -0.18 [V]
ETMY T240 3 DOF Y/V = 0.015 [V]
ITMX T240 1 DOF X/U = -0.277 [V]
ITMX T240 1 DOF Y/V = -0.128 [V]
ITMX T240 1 DOF Z/W = -0.053 [V]
ITMX T240 2 DOF X/U = -0.069 [V]
ITMX T240 2 DOF Y/V = -0.065 [V]
ITMX T240 2 DOF Z/W = -0.074 [V]
ITMX T240 3 DOF X/U = -0.224 [V]
ITMX T240 3 DOF Y/V = -0.042 [V]
ITMX T240 3 DOF Z/W = -0.017 [V]
ITMY T240 1 DOF X/U = 0.081 [V]
ITMY T240 1 DOF Y/V = 0.047 [V]
ITMY T240 1 DOF Z/W = 0.051 [V]
ITMY T240 2 DOF X/U = 0.057 [V]
ITMY T240 2 DOF Y/V = 0.191 [V]
ITMY T240 2 DOF Z/W = 0.13 [V]
ITMY T240 3 DOF Y/V = 0.138 [V]
BS T240 1 DOF X/U = -0.082 [V]
BS T240 1 DOF Y/V = 0.043 [V]
BS T240 2 DOF X/U = 0.144 [V]
BS T240 2 DOF Y/V = 0.276 [V]
BS T240 2 DOF Z/W = 0.086 [V]
BS T240 3 DOF X/U = 0.122 [V]
BS T240 3 DOF Y/V = -0.016 [V]
BS T240 3 DOF Z/W = -0.018 [V]


Assessment complete.
 