Head 3 flow rate looks to be the cause. Attached are two trend plots: one for the past 2 hours and one for the
past 12 hours. The flow rate looked pretty clean for the past 12 hours before getting ragged.
If there were any bubbles in the system because of yesterday's trip, this would be a good candidate for one.
Head 3 flow rate looks to be the cause. Attached are two trend plots: one for the past 2 hours and one for the past 12 hours. The flow rate looked pretty clean for the past 12 hours before getting ragged. If there were any bubbles in the system because of yesterday's trip, this would be a good candidate for one.