Displaying report 1-1 of 1.
Reports until 17:43, Sunday 12 March 2017
H1 General
travis.sadecki@LIGO.ORG - posted 17:43, Sunday 12 March 2017 - last comment - 19:08, Sunday 12 March 2017(34770)
Lockloss 0:40 UTC

PSL tripped. Calling Peter.

Comments related to this report
peter.king@LIGO.ORG - 19:08, Sunday 12 March 2017 (34771)PSL
Head 3 flow rate looks to be the cause.  Attached are two trend plots: one for the past 2 hours and one for the
past 12 hours.  The flow rate looked pretty clean for the past 12 hours before getting ragged.

    If there were any bubbles in the system because of yesterday's trip, this would be a good candidate for one.
Images attached to this comment
Displaying report 1-1 of 1.