Reports until 13:02, Monday 13 March 2017
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 13:02, Monday 13 March 2017 (34788)
CDS O2 restart report: Friday 10th - Sunday 12th March 2017

model restarts logged for Sat 11/Mar/2017* No restarts reported

model restarts logged for Sat 11/Mar/2017 No restarts reported

model restarts logged for Fri 10/Mar/2017 No restarts reported

Note that the reporting code mistakenly reported Sun as Sat in this morning's report. This is because LHO transitioned from PST to PDT at 02:00 Sunday. My code runs at 5 minutes past midnight, and goes back a period of 24 hours to get the previous day's date. When it ran at 00:05 PDT this morning, going back 24 hours ( convert to GPS, subtract 24*60*60 seconds) effectively goes back 25 hours to 23:05 Sat 11th. Other uses of relative time spanning this period may have similar surprises.