Revisions to H2 SUS ITMY & ETMY Simulink models
Dave B., Jeff G.

The Simulink models for H2 SUS ITMY and ETMY were modified today to add the RFM capabilities between the Corner and End-Y stations.  Both models 'h2susitmy.mdl" and "h2susetmy.mdl" been compiled and installed on the frontends 'h2susb478' and 'h2susb6', respectively.  The top level of each custom model needed the inputs re-connected to the common "QUAD_MASTER" library part.  There were six additional inputs added to the "QUAD_MASTER.adl" inputs and three outputs, which were terminated from the top level.  The changes to the top level were also intended to facilitate the use of the newly-installed IPC card on 'h2susb6'. 

Changes saved and committed to the SVN under:
'~/userapps/sus/h2/models/'  as  "h2susitmy.mdl" & "h2susetmy.mdl"
Displaying report 1-1 of 1.