Weekly PSL Status Report

Laser Status: SysStat is good

Front End Power is 34.12W (should be around 30 W)

HPO Output Power is 163.8W

Front End Watch is GREEN

HPO Watch is GREEN

PMC: It has been locked 5 days, 21 hr 27 minutes (should be days/weeks)

Reflected power = 16.03Watts

Transmitted power = 64.35Watts

PowerSum = 80.38Watts.

FSS: It has been locked for 0 days 0 hr and 45 min (should be days/weeks)

TPD[V] = 3.319V (min 0.9V)

ISS: The diffracted power is around 2.0% (should be 3-5%)

Last saturation event was 0 days 0 hours and 45 minutes ago (should be days/weeks)

Possible Issues: