Displaying report 1-1 of 1.
Reports until 00:04, Wednesday 22 March 2017
H1 General
jeffrey.bartlett@LIGO.ORG - posted 00:04, Wednesday 22 March 2017 (34996)
Ops Evening Shift Summary
Ops Shift Log: 03/21/2017, Evening Shift 23:00 – 07:00 (16:00 - 00:00) Time - UTC (PT)
State of H1: Locked at NLN for 2.25 hours at 29.0W and 67.0 Mpc.     
Intent Bit: Observing
Support: Dave B., Sheila, Jonathan
Incoming Operator: Jim

Shift Summary: Ran A2L DTT check – Pitch and Yaw are both somewhat elevated. Tumbleweed baling has finished for the day. Work will continue on the X-Arm tomorrow.

Problem #1 - Started getting OMC DCPD saturations (due to Violin Mode 508.2 ring up), but lost lock before damping. Contacted Sheila and tried to give remote access.

Problem #2 – Could not give Sheila remote access due to a problem with the authentication server. Contacted Jonathan who corrected the problem (FRS 7677 aLOG #43993).

Problem #3 – There was a problem with the Foton filter files generated after last Tuesday’s maintenance window until today at 13:00, when Jim B. fixed this problem. See aLOG #43992 for description. Contacted Dave B. who rebuilt the Foton files for the SUSs and H1OMCPI. When I reloaded, the filter files the WDs for ITMX & ETMY tripped. By the time this was all squared away the violin modes had calmed down a bit.

Relocked the IFO without the ALS_DIFF problem had during the day shift. I had to dress up BS Yaw a little bit, but no other tweaks were required.

We were back to Observing in time to receive a GRB alert.

   Activity Log: Time - UTC (PT)
23:00 (16:00) Take over from TJ
23:20 (16:20) Ran A2L check script
00:13 (17:13) Bubba – Tumbleweed baling finished for the day
01:01 (18:01) Damp PI Mode-27
02:28 (19:28) OMC DCPD Saturation
02:38 (19:38) Lockloss – Violin mode ringing up
04:36 (21:36) Relocked at NLN and back to Observing
04:45 (21:45) Damp PI Mode-27
04:59 (21:59) Damp PI Mode-27
05:06 (22:06) GRB Alert – One hour stand-down
05:10 (22:10) Damp PI Mode-27
06:06 (23:06) End stand-down
07:00 (00:00) Turn over to Jim

 

 

Displaying report 1-1 of 1.