H1 glitch, Verbal Alarms shows OMC DCPD Saturation, but date and time are incorrect, maybe the claimed source of the glitch is too
Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 09:29, Monday 27 March 2017 (35107)OpsInfo

This is a classic case of "Middle-Click Syndrome". Someone highlighted that OMC DCPD line in the Verbal Terminal and then accidentally middle clicked later. I checked this by first checking the Verbal logs to make sure it wasn't in there, and then I went to the alarms work station and middle clicked in the Verbal Terminal. Sure enough, the same March 10 OMC DCPD saturation message showed up.