Reports until 10:45, Tuesday 28 March 2017
H1 DetChar (DetChar, PEM)
keita.kawabe@LIGO.ORG - posted 10:45, Tuesday 28 March 2017 - last comment - 08:50, Monday 03 April 2017(35136)
glitches that are seemingly n*12.1Hz

See red and blue VS green. Bumps are at around [4, 5, 6, 7, 8]*12.125 Hz or so.

When it was really bad (red), it was easily identifiable in detchar summary page, not so when it was mildly bad (blue).

Images attached to this report
Comments related to this report
duo.tao@LIGO.ORG - 23:49, Friday 31 March 2017 (35256)DetChar

I ran coherence tool on these lines. I first tried to find a comb over there but failed. Then I tried to find them as single lines. I looked for 6 single lines: 12.125Hz, 48.5Hz, 60.625Hz, 72.75Hz, 84.875Hz, 97Hz. Two of them are not found in the coherence tool. Here are the results:

12.5Hz: https://ldas-jobs.ligo-wa.caltech.edu/~duo.tao/O2_line_12.125/index.html (Weak results and the structure does not look like a single line)

48.5Hz: https://ldas-jobs.ligo-wa.caltech.edu/~duo.tao/O2_line_48.5/index.html (Found in four of the weeks, in some EX and EY magnetometers. There are some channels that do not look like a single line. But there seems to be something going on so I showed them.)

60.625Hz: https://ldas-jobs.ligo-wa.caltech.edu/~duo.tao/O2_line_60.625/index.html (Not found)

72.75Hz: https://ldas-jobs.ligo-wa.caltech.edu/~duo.tao/O2_line_72.75/index.html (Not found)

84.875Hz: https://ldas-jobs.ligo-wa.caltech.edu/~duo.tao/O2_line_84.875/index.html (Weak. Only found in one channel and the structure does not look a single line)

97Hz: https://ldas-jobs.ligo-wa.caltech.edu/~duo.tao/O2_line_97/index.html (Found in many EX and EY magnetometers)

keita.kawabe@LIGO.ORG - 08:50, Monday 03 April 2017 (35286)

Robert's measurements seem to suggest that this is the resonance of one of the baffles.

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=35166